Calculate water-heater recovery capacity from temperature rise, efficiency and either GPH demand or heater input.

Temperature rise

90 °F

Useful water-heating load

75 MBH

Required heater input

93.7 MBH

Recovery from known input

107 GPH

Recovery is only one part of water-heater sizing. Storage, peak draw, recirculation losses and manufacturer first-hour ratings may govern.

Your next design step

Coordinate hot-water demand and distribution.

Keep recovery calculations with water-heater selection. Use MEPFlow to lay out domestic-water piping and fixture connections.

Keep this check: Review storage, draw profile, entering temperature, efficiency and the selected heater’s rating.

7 days free. Then $49 USD/month. Card required. Cancel anytime. Create a project and choose your workflow. Calculator inputs do not transfer automatically.

How the Water Heater Recovery Calculator Works

Heating one US gallon of water by one degree Fahrenheit requires approximately 8.33 Btu. Multiplying gallons per hour by temperature rise and 8.33 gives the useful heat transferred to the water.

To estimate required heater input, divide useful heat by thermal efficiency. To estimate recovery from a known heater input, multiply input by efficiency and divide by 8.33 × temperature rise.

Recovery is only one part of water-heater sizing. Storage volume, peak draw profile, first-hour demand, mixing, recirculation losses, standby losses and manufacturer ratings can all govern final equipment selection.

Calculation basis

Useful Heat ≈ 8.33 × GPH × ΔT

When to Use This Calculator

  • Commercial DHW recovery checks
  • Storage heater screening
  • Boiler-to-DHW capacity checks
  • Temperature-rise sensitivity

Engineering Checks Before Final Design

  • Use manufacturer-rated thermal efficiency when available.
  • Peak storage demand can govern even when recovery is adequate.
  • Include recirculation and distribution losses in final sizing.

Related Engineering Guides

Continue with the calculation methods, design checks and worked examples most closely related to this tool.

Frequently Asked Questions

What is water-heater recovery?

Recovery is the rate at which a heater can raise incoming water to the target delivery temperature, commonly expressed in gallons per hour.

Why does colder inlet water reduce recovery?

A larger temperature rise requires more heat per gallon, so the same heater input produces fewer gallons per hour.

Does efficiency affect required input?

Yes. Heater input must be higher than useful water-heating output when efficiency is below 100%.

Does this choose storage tank size?

No. Storage sizing requires the building's peak draw profile and recovery/storage strategy.

Plumbing
Calculate water-supply fixture units and a preliminary pipe size using NPC 2020. Includes private/public fixtures, direct-flush valves and worked examples.
Plumbing
Add drainage fixtures, calculate NPC 2020 fixture units, and size sanitary branches, stacks, building drains and sewers by hydraulic load and slope.
Plumbing
Calculate water volume in one pipe or a whole pipe inventory, in litres, US gallons and Imperial gallons.
Plumbing
Calculate pipe pressure loss, fitting losses, velocity and head loss with Darcy–Weisbach in metric or US units.
Plumbing
Free domestic hot water recirculation calculator. Convert piping heat loss and allowable temperature drop into required recirculation GPM and L/s.
Plumbing
Calculate water velocity from flow and inside diameter. Use L/s, L/min, m³/h, US GPM or Imperial GPM and check a target velocity.