Sanitary Drainage Design Software

Sanitary Drainage Design Software. Follow the Fixture Load Downstream.

Lay out gravity sanitary drainage over a PDF plan. Review fixture units, branch and stack pipe sizing, building-drain slope and fall in MEPFlow’s Sanitary Drainage module.

30 days free. Then $50 USD/month. No credit card required.

Two floor branches enter a vertical sanitary stack. Total stack load, maximum load from one storey and the sloped building drain require separate checks.Upper storey: 8.5 FULower storey: 11.5 FUStack: 20 FU totalLargest storey: 11.5 FUSeparate branch checksBuilding drain → slope check
Two floor branches enter a vertical sanitary stack. Total stack load, maximum load from one storey and the sloped building drain require separate checks.

Sanitary sizing illustration · MEPFlow example project.

The connected workflow

Keep the design and the engineering together.

MEPFlow’s separate Drainage module connects a sanitary fixture layout with gravity pipe-sizing checks. It uses drainage fixture units and Canadian NPC 2020 reference tables, with distinct checks for branches, stacks and building drains. It does not reuse domestic-water demand or pump calculations.

  • Place supported sanitary fixtures and connected downstream runs.
  • Review branch, total-stack and busiest-storey fixture-unit loads.
  • Apply nominal pipe sizing with slope-specific building-drain checks.
  • Inspect pipe length, fall, invert elevations and sizing warnings.

Design scope: gravity sanitary pipe sizing. Venting, trap arms, cleanouts, stack offsets, pumped wastewater and storm drainage require separate design. Verify the adopted code edition and local amendments for your project.

Two floor branches enter a vertical sanitary stack. Total stack load, maximum load from one storey and the sloped building drain require separate checks.Upper storey: 8.5 FULower storey: 11.5 FUStack: 20 FU totalLargest storey: 11.5 FUSeparate branch checksBuilding drain → slope check
Two floor branches enter a vertical sanitary stack. Total stack load, maximum load from one storey and the sloped building drain require separate checks.

01 / System layout

Design from the floor plan.

Use the Drainage module inside a project to apply a shared PDF drawing, place supported sanitary fixtures, connect directed branches/mains and add vertical floor stacks. Inspect fixture classifications, flow direction and node connections before sizing.

See how to get started

02 / Calculations & sizing

From fixture layout to a reviewed gravity network

  1. 01

    Place fixtures and connect

    Apply the scaled drawing, choose supported sanitary fixture types and connect directed branches, mains and floor stacks.

  2. 02

    Review load and fall

    Inspect fixture units, connection direction, invert levels and design slopes. Follow the accumulated load downstream and check the busiest storey on a stack.

  3. 03

    Apply sizing and inspect

    Run Auto-size, review nominal diameters and warnings, and check any locked size overrides. Recheck the result after altering geometry or fixture demand.

Sanitary Drainage Checks

A single fixture-unit total cannot represent every part of a gravity drainage system. The module keeps these checks separate.

Fixture hydraulic load

Supported fixture classifications establish drainage fixture units. Verify private/public use and the specific fixture arrangement; water-supply fixture units are a different quantity.

Branches and stacks

Branch capacity and stack capacity use different table checks. Stacks also need the maximum load entering from one storey, so total fixture units alone are insufficient.

Building drains and slope

Building-drain capacity depends on the applicable pipe size and selected slope. Review actual fall and inverts as well as the nominal sizing result.

Connections and overrides

The layout provides directed connections and vertical floor stacks. Locked pipe sizes remain visible for review, and invalid or incomplete network conditions generate warnings.

Explore methods and scope

03 / Review your design

When the design changes

Connected fixture units and warnings update as the network changes. Apply Auto-size to choose supported nominal pipe sizes, or lock a deliberate size override for review. Inspect invert elevations, actual fall and design slope. Changed geometry or engineering inputs can make the previous sizing receipt stale.

Results and outputs

The module presents pipe-by-pipe fixture units, selected sizes, lengths, falls, slopes and warnings on screen. It covers gravity sanitary pipe sizing only. Venting, trap arms, cleanouts, stack offsets, pumped waste, stormwater and drainage report/drawing exports are not included in this advertised scope.

Built for your work

For sanitary drainage layout and preliminary sizing

Sanitary drainage sizing is more than totaling a fixture schedule. Branch load, total stack load, the busiest storey and building-drain slope are separate checks. A disconnected schedule can hide an incorrect downstream connection or a branch with insufficient fall.

  • Plumbing designers checking Canadian gravity sanitary networks.
  • Mechanical consultants reviewing fixture schedules and downstream loads.
  • Contractors working through routing and fall with the design team.
  • Engineers who will complete venting and jurisdiction-specific checks separately.

The MEPFlow community

Built with your feedback.

Better tools start with the people who use them.

Using MEPFlow on a project?

We’re gathering customer reviews from designers. Tell us how MEPFlow fits your work, what helps, and what you’d like to see next.

Share Your Experience

A few more details

Your questions, answered.

Is sanitary drainage available in MEPFlow?

Yes. Sanitary Drainage is included alongside the other MEPFlow design modules. Its advertised scope is gravity sanitary layout and pipe sizing with fixture-unit, slope, fall and stack-load review. Review the results and complete checks outside that scope separately.

Does the module design stormwater drainage?

No. Rainfall intensity, roof catchment areas, stormwater sizing and storm drainage networks are outside the current advertised module scope.

Does it size vents and trap arms?

No. A sanitary pipe-size result does not complete venting, trap-arm, cleanout or fitting design. Those items and local amendments need a separate review.

What Canadian plumbing code is the sizing based on?

The module uses NPC 2020 reference fixture-load and sanitary capacity tables. This is a stated calculation basis, not a certification of the complete design. Confirm the code edition adopted in your province and the local authority requirements.

How are drainage fixture units different from water-supply fixture units?

Drainage fixture units describe hydraulic load for the sanitary system. Water-supply fixture units are used for demand in the pressurized supply system. Their tables and calculations are different and should not be substituted.

Can I check a sanitary pipe size for free?

Yes. The public Canadian sanitary drain calculator and worked guide are available without an account. Use the application when you want the connected fixture layout and network review.

Does drainage include pump duty or a report export?

Pumped waste and drainage report/drawing exports are not part of this module’s published scope. Review the available pipe-by-pipe results and warnings on screen.

Have a question about your project? Talk to us