Skip to content

HVAC duct design software

HVAC duct design software. From airflow to sized layout.

Design HVAC ductwork with connected airflow, equal-friction sizing, fitting losses and critical-path pressure workflows. Start with MEPFlow's free duct sizer.

7 days free. Then $49 USD/month. Card required. Cancel anytime.

MEPFlow / HVAC DuctworkIn your browser
One plan. Connected calculations.

See MEPFlow in action

From room airflow to a sized duct network.

See connected terminals, automatic duct sizing, pressure review and 3D visualization working together on the same plan.

Try it yourself

Try HVAC ductwork in MEPFlow.

Use prepared room loads, connect diffusers and size the duct system.

One form unlocks all four demos · No account or card needed
HVAC DuctworkGuided demo
HVAC Ductwork example in the MEPFlow workspace

HVAC Ductwork

Use prepared room loads, connect diffusers and size the duct system.

Click the highlighted controls or use Got it.

Follow the highlights. Use Back to revisit a step.

The connected workflow

Keep the design and the engineering together.

A single duct diameter is only one part of a real HVAC design. MEPFlow is built around the system workflow: establish airflow, size sections, account for fittings and follow the pressure path that drives fan selection and coordination.

  • Size round and rectangular ductwork from airflow, velocity or friction constraints.
  • Keep fitting losses and critical-path pressure visible as the system develops.
  • Connect ventilation and air-distribution decisions to downstream duct sizing.
  • Check individual sections instantly with the free public duct sizer.

Inside the workflow

A closer look at the sized network.

Follow terminal airflow, inspect the pressure calculation and review the same duct system in plan and 3D.

01 / Duct design

CFM where you need it

Read terminal and branch airflow alongside calculated duct diameters.

Dining-room supply diffusers, return grille and branches with airflow and duct-size labels
CFM at the terminals and through the branchesMEPFlow · Example project

02 / Duct design

Open the pressure breakdown

See estimated ESP, critical-route length and the contribution of ducts, elbows, junctions and terminals.

AHU air-pressure section with ESP estimate, critical-route length and full pressure breakdown
ESP, critical route and component lossesMEPFlow · Example project

03 / Duct design

Follow the network from above

A simplified top view makes the supply and return branches easier to trace.

Top-down duct system with thick blue supply ducts, red return ducts and connected terminals
A clear top view of the duct networkMEPFlow · Example project

04 / Duct design

Inspect duct routing in 3D

Review the duct system inside the room model and explain the routing to your team.

Watch the duct workflow
Duct system shown in perspective inside translucent rooms
Inspect the duct network in 3DMEPFlow · Example project

MEPFlow example project. Images show the relevant part of each workflow.

Supply and return main ducts with branches to reception and office terminals
Follow the main run and its branchesMEPFlow · Example project

01 / System layout

Design from the floor plan.

Apply your calibrated PDF floor plan, place equipment and air terminals, and connect duct runs. Work with supply and return air and the available exhaust/outdoor-air services. Inspect endpoints and branch connectivity before relying on accumulated airflow.

See how to get started

02 / Calculations & sizing

From zone airflow to duct system

  1. 01

    Calculate airflow

    Establish outdoor-air and zone airflow requirements using the inputs and method appropriate to the space.

  2. 02

    Size duct sections

    Apply equal-friction or velocity constraints to round and rectangular sections while reviewing practical limits.

  3. 03

    Follow the critical path

    Include straight-duct and fitting losses so pressure requirements are based on the system path, not an isolated section.

What a complete HVAC duct design workflow needs

Useful duct software has to connect airflow, geometry and pressure rather than treating each section as an isolated ductulator calculation. MEPFlow keeps the major sizing checks visible so the designer can understand why a section or system result changes.

Airflow basis

Duct sizing starts with a defensible airflow. Room loads, ventilation requirements and air-distribution decisions establish the CFM that each branch and main section must carry.

Friction and velocity

Equal-friction sizing provides a repeatable starting point, while velocity checks help identify sections that may create excessive pressure loss, noise or impractical dimensions.

Round and rectangular ducts

The design workflow distinguishes actual rectangular cross-sectional area from equivalent-round relationships used for friction, so velocity and pressure calculations are based on the correct geometry.

Fittings and equivalent length

Elbows, transitions, tees and other fittings can contribute a large share of system resistance. A complete pressure calculation therefore includes fitting losses rather than relying on straight-duct friction alone.

Critical-path pressure

Fan pressure is governed by the path with the controlling total loss. MEPFlow is intended to carry section losses into a system-level critical-path review instead of stopping at duct size.

Diffusers and grilles

Terminal selection depends on airflow, face velocity, throw, pressure drop and acoustics. The duct workflow should remain coordinated with the diffuser and grille decisions at the end of each branch.

Explore methods and scope

03 / Review your design

When the design changes

Use manual terminal airflow or supported room-load assignments as the design basis. After changing demands, geometry or connections, run Auto-size System and review the displayed results and warnings. A changed layout may need a new sizing pass; the software does not make every engineering decision automatically.

Results and outputs

Review selected duct dimensions, airflow, velocity and available section/system pressure results. Export the drawing to a PDF overlay when an original PDF is available, or PNG. Use fan-pressure results with the equipment and fitting assumptions you have actually entered; they do not replace a manufacturer fan-curve or acoustic review.

Built for your work

Use cases for duct design teams

Sizing each duct in a spreadsheet leaves a second job: keeping branch airflows, terminal connections and dimensions consistent on the drawing. A late terminal or route change can make the old size labels and pressure calculation misleading.

  • Consulting engineers developing commercial HVAC distribution systems.
  • Designers replacing disconnected duct-sizing spreadsheets and reference wheels.
  • Teams that need repeatable methods and clearer review of sizing assumptions.
  • Engineers working in imperial or metric units across Canada and the United States.

The MEPFlow community

Built with your feedback.

Better tools start with the people who use them.

Using MEPFlow on a project?

We’re gathering customer reviews from designers. Tell us how MEPFlow fits your work, what helps, and what you’d like to see next.

Share Your Experience

A few more details

Your questions, answered.

What is equal-friction duct sizing?

Equal-friction sizing selects duct dimensions so straight sections have a consistent pressure-loss rate per unit length. The final system design still needs fitting losses, the critical path, acoustics and fan pressure.

Can MEPFlow size rectangular ducts?

Yes. The duct tools support round and rectangular geometry and distinguish actual rectangular velocity from the equivalent-round basis used for friction calculations.

How do fitting losses affect duct design?

Elbows, transitions, tees, dampers and other components add resistance beyond straight-duct friction. Their losses must be included on each path before the fan pressure requirement can be evaluated.

What is the critical path in a duct system?

The critical path is the route from the fan to a terminal that produces the controlling total pressure loss after straight duct, fittings and equipment losses are considered.

Is the free duct sizer a complete duct design tool?

No. It sizes an individual section. MEPFlow's broader workflow is intended to carry sizing into layouts, fitting losses and critical-path pressure calculations.

Can I use metric and imperial units?

Yes. The duct sizing calculator supports both systems while keeping the underlying calculation consistent.

Have a question about your project? Talk to us

Automatic MEP sizing

The spreadsheet chain
ends here.

Loads. Airflow. Ductwork. Pipework. Hydronics. Drainage. 3D. One connected engineering workflow.